Header logo is


2016


Steering control of a water-running robot using an active tail
Steering control of a water-running robot using an active tail

Kim, H., Jeong, K., Sitti, M., Seo, T.

In Intelligent Robots and Systems (IROS), 2016 IEEE/RSJ International Conference on, pages: 4945-4950, October 2016 (inproceedings)

Abstract
Many highly dynamic novel mobile robots have been developed being inspired by animals. In this study, we are inspired by a basilisk lizard's ability to run and steer on water surface for a hexapedal robot. The robot has an active tail with a circular plate, which the robot rotates to steer on water. We dynamically modeled the platform and conducted simulations and experiments on steering locomotion with a bang-bang controller. The robot can steer on water by rotating the tail, and the controlled steering locomotion is stable. The dynamic modelling approximates the robot's steering locomotion and the trends of the simulations and experiments are similar, although there are errors between the desired and actual angles. The robot's maneuverability on water can be improved through further research.

pi

DOI [BibTex]

2016


DOI [BibTex]


Targeting of cell mockups using sperm-shaped microrobots in vitro
Targeting of cell mockups using sperm-shaped microrobots in vitro

Khalil, I. S., Tabak, A. F., Hosney, A., Klingner, A., Shalaby, M., Abdel-Kader, R. M., Serry, M., Sitti, M.

In Biomedical Robotics and Biomechatronics (BioRob), 2016 6th IEEE International Conference on, pages: 495-501, July 2016 (inproceedings)

Abstract
Sperm-shaped microrobots are controlled under the influence of weak oscillating magnetic fields (milliTesla range) to selectively target cell mockups (i.e., gas bubbles with average diameter of 200 μm). The sperm-shaped microrobots are fabricated by electrospinning using a solution of polystyrene, dimethylformamide, and iron oxide nanoparticles. These nanoparticles are concentrated within the head of the microrobot, and hence enable directional control along external magnetic fields. The magnetic dipole moment of the microrobot is characterized (using the flip-time technique) to be 1.4×10-11 A.m2, at magnetic field of 28 mT. In addition, the morphology of the microrobot is characterized using Scanning Electron Microscopy images. The characterized parameters and morphology are used in the simulation of the locomotion mechanism of the microrobot to prove that its motion depends on breaking the time-reversal symmetry, rather than pulling with the magnetic field gradient. We experimentally demonstrate that the microrobot can controllably follow S-shaped, U-shaped, and square paths, and selectively target the cell mockups using image guidance and under the influence of the oscillating magnetic fields.

pi

DOI [BibTex]

DOI [BibTex]


Analysis of the magnetic torque on a tilted permanent magnet for drug delivery in capsule robots
Analysis of the magnetic torque on a tilted permanent magnet for drug delivery in capsule robots

Munoz, F., Alici, G., Zhou, H., Li, W., Sitti, M.

In Advanced Intelligent Mechatronics (AIM), 2016 IEEE International Conference on, pages: 1386-1391, July 2016 (inproceedings)

Abstract
In this paper, we present the analysis of the torque transmitted to a tilted permanent magnet that is to be embedded in a capsule robot to achieve targeted drug delivery. This analysis is carried out by using an analytical model and experimental results for a small cubic permanent magnet that is driven by an external magnetic system made of an array of arc-shaped permanent magnets (ASMs). Our experimental results, which are in agreement with the analytical results, show that the cubic permanent magnet can safely be actuated for inclinations lower than 75° without having to make positional adjustments in the external magnetic system. We have found that with further inclinations, the cubic permanent magnet to be embedded in a drug delivery mechanism may stall. When it stalls, the external magnetic system's position and orientation would have to be adjusted to actuate the cubic permanent magnet and the drug release mechanism. This analysis of the transmitted torque is helpful for the development of real-time control strategies for magnetically articulated devices.

pi

DOI [BibTex]

DOI [BibTex]


Patches, Planes and Probabilities: A Non-local Prior for Volumetric {3D} Reconstruction
Patches, Planes and Probabilities: A Non-local Prior for Volumetric 3D Reconstruction

Ulusoy, A. O., Black, M. J., Geiger, A.

In IEEE Conf. on Computer Vision and Pattern Recognition (CVPR), IEEE International Conference on Computer Vision and Pattern Recognition (CVPR), June 2016 (inproceedings)

Abstract
In this paper, we propose a non-local structured prior for volumetric multi-view 3D reconstruction. Towards this goal, we present a novel Markov random field model based on ray potentials in which assumptions about large 3D surface patches such as planarity or Manhattan world constraints can be efficiently encoded as probabilistic priors. We further derive an inference algorithm that reasons jointly about voxels, pixels and image segments, and estimates marginal distributions of appearance, occupancy, depth, normals and planarity. Key to tractable inference is a novel hybrid representation that spans both voxel and pixel space and that integrates non-local information from 2D image segmentations in a principled way. We compare our non-local prior to commonly employed local smoothness assumptions and a variety of state-of-the-art volumetric reconstruction baselines on challenging outdoor scenes with textureless and reflective surfaces. Our experiments indicate that regularizing over larger distances has the potential to resolve ambiguities where local regularizers fail.

avg ps

YouTube pdf poster suppmat Project Page [BibTex]

YouTube pdf poster suppmat Project Page [BibTex]


Semantic Instance Annotation of Street Scenes by 3D to 2D Label Transfer
Semantic Instance Annotation of Street Scenes by 3D to 2D Label Transfer

Xie, J., Kiefel, M., Sun, M., Geiger, A.

In IEEE Conf. on Computer Vision and Pattern Recognition (CVPR), IEEE International Conference on Computer Vision and Pattern Recognition (CVPR), June 2016 (inproceedings)

Abstract
Semantic annotations are vital for training models for object recognition, semantic segmentation or scene understanding. Unfortunately, pixelwise annotation of images at very large scale is labor-intensive and only little labeled data is available, particularly at instance level and for street scenes. In this paper, we propose to tackle this problem by lifting the semantic instance labeling task from 2D into 3D. Given reconstructions from stereo or laser data, we annotate static 3D scene elements with rough bounding primitives and develop a probabilistic model which transfers this information into the image domain. We leverage our method to obtain 2D labels for a novel suburban video dataset which we have collected, resulting in 400k semantic and instance image annotations. A comparison of our method to state-of-the-art label transfer baselines reveals that 3D information enables more efficient annotation while at the same time resulting in improved accuracy and time-coherent labels.

avg ps

pdf suppmat Project Page Project Page [BibTex]

pdf suppmat Project Page Project Page [BibTex]


Sperm-shaped magnetic microrobots: Fabrication using electrospinning, modeling, and characterization
Sperm-shaped magnetic microrobots: Fabrication using electrospinning, modeling, and characterization

Khalil, I. S., Tabak, A. F., Hosney, A., Mohamed, A., Klingner, A., Ghoneima, M., Sitti, M.

In Robotics and Automation (ICRA), 2016 IEEE International Conference on, pages: 1939-1944, May 2016 (inproceedings)

Abstract
We use electrospinning to fabricate sperm-shaped magnetic microrobots with a range of diameters from 50 μm to 500 μm. The variables of the electrospinning operation (voltage, concentration of the solution, dynamic viscosity, and distance between the syringe needle and collector) to achieve beading effect are determined. This beading effect allows us to fabricate microrobots with similar morphology to that of sperm cells. The bead and the ultra-fine fiber resemble the morphology of the head and tail of the sperm cell, respectively. We incorporate iron oxide nanoparticles to the head of the sperm-shaped microrobot to provide a magnetic dipole moment. This dipole enables directional control under the influence of external magnetic fields. We also apply weak (less than 2 mT) oscillating magnetic fields to exert a magnetic torque on the magnetic head, and generate planar flagellar waves and flagellated swim. The average speed of the sperm-shaped microrobot is calculated to be 0.5 body lengths per second and 1 body lengths per second at frequencies of 5 Hz and 10 Hz, respectively. We also develop a model of the microrobot using elastohydrodynamics approach and Timoshenko-Rayleigh beam theory, and find good agreement with the experimental results.

pi

DOI [BibTex]

DOI [BibTex]


Deep Discrete Flow
Deep Discrete Flow

Güney, F., Geiger, A.

Asian Conference on Computer Vision (ACCV), 2016 (conference) Accepted

avg ps

pdf suppmat Project Page [BibTex]

pdf suppmat Project Page [BibTex]


no image
Statische und dynamische Magnetisierungseigenschaften nanoskaliger Überstrukturen

Gräfe, J.

Universität Stuttgart, Stuttgart (und Cuvillier Verlag, Göttingen), 2016 (phdthesis)

mms

[BibTex]

[BibTex]


no image
Gepinnte Bahnmomente in magnetischen Heterostrukturen

Audehm, P.

Universität Stuttgart, Stuttgart (und Cuvillier Verlag, Göttingen), 2016 (phdthesis)

mms

[BibTex]

[BibTex]


no image
Austauschgekoppelte Moden in magnetischen Vortexstrukturen

Dieterle, G.

Universität Stuttgart, Stuttgart, 2016 (phdthesis)

mms

[BibTex]

[BibTex]


no image
Density matrix calculations for the ultrafast demagnetization after femtosecond laser pulses

Weng, Weikai

Universität Stuttgart, Stuttgart, 2016 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Helium und Hydrogen Isotope Adsorption and Separation in Metal-Organic Frameworks

Zaiser, Ingrid

Universität Stuttgart, Stuttgart (und Cuvillier Verlag, Göttingen), 2016 (phdthesis)

mms

[BibTex]

[BibTex]

2007


no image
A strategy for vision-based controlled pushing of microparticles

Lynch, N. A., Onal, C., Schuster, E., Sitti, M.

In Robotics and Automation, 2007 IEEE International Conference on, pages: 1413-1418, 2007 (inproceedings)

pi

[BibTex]

2007


[BibTex]


no image
On the theory of magnetization dynamics of non-collinear spin systems in the s-d model

De Angeli, L.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Zur ab-initio Elektronentheorie des Magnetismus bei endlichen Temperaturen

Dietermann, F.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Röntgenzirkulardichroische Untersuchungen an ferromagnetischen verdünnten Halbleitersystemen

Tietze, T.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Low-dimensional Fe on vicinal Ir(997): Growth and magnetic properties

Kawwam, M.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Micromagnetic simulations of switching processes and the role of thermal fluctuations

Macke, S.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Physisorption von Wasserstoff in neuen Materialien mit gro\sser spezifischer Oberfläche

Schmitz, B.

Universität Bonn, Bonn, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Towards spin injection into silicon

Dash, S. P.

Universität Stuttgart, Stuttgart, 2007 (phdthesis)

mms

link (url) [BibTex]

link (url) [BibTex]


no image
Bestimmung der kritischen Schichtdicken ferromagnetischer Plättchen für Eindomänenverhalten

Soehnle, S.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Autonomous 2D microparticle manipulation based on visual feedback

Onal, C. D., Sitti, M.

In Advanced intelligent mechatronics, 2007 IEEE/ASME international conference on, pages: 1-6, 2007 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Zeitaufgelöste Röntgenmikroskopie an magnetischen Mikrostrukturen

Puzic, A.

Universität Stuttgart, Stuttgart, 2007 (phdthesis)

mms

link (url) [BibTex]

link (url) [BibTex]


no image
Vortex dynamics studied by time-resolved X-ray microscopy

Chou, K. W.

Universität Stuttgart, Stuttgart, 2007 (phdthesis)

mms

link (url) [BibTex]

link (url) [BibTex]


no image
Resonante magnetische Reflektometrie an Ferromagnet/Paramagnet Heterostrukturen

Ferreras Paz, V.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
STRIDE: A highly maneuverable and non-tethered water strider robot

Song, Y. S., Sitti, M.

In Robotics and Automation, 2007 IEEE International Conference on, pages: 980-984, 2007 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Dry spinning polymeric nano/microfiber arrays using glass micropipettes with controlled porosities and fiber diameters

Nain, A. S., Gupta, A., Amon, C., Sitti, M.

In Nanotechnology, 2007. IEEE-NANO 2007. 7th IEEE Conference on, pages: 728-732, 2007 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Herstellung und Charakterisierung dünner Niob-Schichten auf verschiedenen Substraten

Mayer, M. W. R.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Formation of hard magnetic L10-FePt/FePd monolayers from elemental multilayers

Goo, N. H.

Universität Stuttgart, Stuttgart, 2007 (phdthesis)

mms

link (url) [BibTex]

link (url) [BibTex]


no image
Microrobotically fabricated biological scaffolds for tissue engineering

Nain, A. S., Chung, F., Rule, M., Jadlowiec, J. A., Campbell, P. G., Amon, C., Sitti, M.

In Robotics and Automation, 2007 IEEE International Conference on, pages: 1918-1923, 2007 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Bacterial flagella assisted propulsion of patterned latex particles: Effect of particle size

Behkam, B., Sitti, M.

In Nanotechnology, 2007. IEEE-NANO 2007. 7th IEEE Conference on, pages: 723-727, 2007 (inproceedings)

pi

Project Page [BibTex]

Project Page [BibTex]


no image
A scaled bilateral control system for experimental 1-D teleoperated nanomanipulation applications

Onal, C. D., Pawashe, C., Sitti, M.

In Intelligent Robots and Systems, 2007. IROS 2007. IEEE/RSJ International Conference on, pages: 483-488, 2007 (inproceedings)

pi

[BibTex]

[BibTex]


no image
Zur ab-initio Elektronentheorie stark nichtkollinearer Spinsysteme

Köberle, I.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Theorie der Kernspektroskopie mit zirkular polarisierter Gammastrahlung

Engelhart, W.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Untersuchung der Adsorption von Wasserstoff in porösen Materialien

Hönes, K.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Untersuchung der mechanischen Eigenschaften dünner Chromschichten

Jüllig, P.

Universität Stuttgart, Stuttgart, 2007 (mastersthesis)

mms

[BibTex]

[BibTex]


no image
Geometric Image Synthesis

Alhaija, H. A., Mustikovela, S. K., Geiger, A., Rother, C.

(conference)

avg

Project Page [BibTex]


Project Page [BibTex]